Sustainable Data Center Containment Technology

Complete green infrastructure solutions that maximize performance while minimizing environmental impact

Hot Aisle
Containment

cold-aisle-containment-icon

Cold Aisle
Containment

Cage System

 

Hot Aisle Containment​

Hot Aisle Containment (HAC) works by isolating the return air (hot air) from the server so that it does not mix with the supply air (cool air) from the cooling unit.

All return air (hot air) from the server is recirculated back into the return duct of the cooling unit.

In HAC, the area above the rack is usually covered with a vertical partition up to the data center ceiling.

product-hot-aisle

Environmental Benefits:​

material-symbols-icon

Zero Power Operation

No energy consumption during normal operations

mdi_periodic-table-carbon-dioxide-icon

42% Carbon Reduction

Dramatic decrease in cooling-related emissions

Recycable Materials

100% aluminum construction for end-of-life recycling

hugeicons-battery-eco-charging-icon

Green Manufacturing

Sustainable production process with minimal waste

Technical Specifications:

Eco Pivot Ceiling Panels:
Material: 100% recyclable lightweight aluminum frame
Windows: Lead-free 10mm polycarbonate (recyclable)
Operation: Energy-free electromagnetic system
Safety: Zero-power gravity emergency release
Installation: Minimal-waste self-standing design

Green Power Supply System:
Efficiency: Energy Star qualified low-power design
Standby Power: Only 12W continuous (minimal grid impact)
Recyclable Components: RoHS compliant construction
Green Packaging: Minimal, recyclable packaging materials

Green Power Supply System:
Carbon Footprint: 42% reduction in cooling emissions
Energy Impact: Up to 1,860kW annual power reduction
Waste Reduction: Zero operational waste generation
Green ROI: Environmental payback in 51 days

How Products Work

1-image

Sustainable Heat Containment

Server exhaust air is captured within an eco-efficient sealed environment, preventing energy waste from hot/cold air mixing.

2-image

Zero-Waste Direct Return

Hot air travels directly to cooling units through optimized pathways, eliminating energy loss and reducing carbon emissions.

3-image

Maximum Green Efficiency

Cooling units operate at peak efficiency with minimal power consumption, dramatically reducing environmental impact.

4-image

Environmental & Financial Savings

Achieve up to 58% reduction in cooling energy consumption while meeting sustainability targets and reducing operational costs.

how-product-1

Cold Aisle Containment

Cold Aisle Containment (CAC) works by isolating the supply air (cold) from the cooling unit so that it remains near the air inlet of the server and ICT devices, preventing it from mixing with the exhaust air (hot) from the devices.


All return air (hot) from the servers can flow throughout the room.


In CAC, the area above the rack is usually covered with horizontal and vertical partitions.

product-cold-aisle

Environmental Benefits:​

material-symbols-icon

50% Energy Waste Elimination

No cooling

air loss to

environment

mdi_periodic-table-carbon-dioxide-icon

Carbon Neutral Operation

No ongoing

emissions

during use

Sustainable Materials

Eco-friendly aluminum and recyclable components

hugeicons-battery-eco-charging-icon

Green Building Support

LEED

certification

contribution

Technical Specifications:

Sustainable Sliding Door System:
Frame: 100% recyclable aluminum with minimal environmental impact
Operation: Zero-energy mechanical system, no motors required
Windows: Recyclable polycarbonate visibility panels
Access: Manual emergency release (no power required)
Customization: Modular design reduces material waste

Green Common Features (Both Systems):
Materials: Powder-coated recyclable aluminum (zero VOC)
Installation: Low-impact setup with minimal construction waste
Maintenance: Sustainable operation with no chemical cleaners required
End-of-Life: 95% recyclable components
Green Warranty: Environmental performance guarantee included

Environmental Performance:
Energy Savings: 50% reduction in cooling energy waste
Air Efficiency: 60% more effective air utilization
Carbon Impact: Significant reduction in cooling-related emissions
Sustainability: Supports corporate ESG goals and green certifications

technical-image-2

How Products Work

1-image

Green Air Preservation Cool

supply air is preserved within the eco-containment, maintaining optimal temperature without energy waste from floor to equipment.

2-image

Sustainable Precision Delivery

Cooled air reaches server intakes at perfect temperature without contamination, eliminating the need for overcooling and reducing energy waste.

3-image

Eco-Friendly Density Support

Support Consistent sustainable air supply enables higher rack densities while maintaining minimal environmental impact and energy consumption.

4-image

Green Efficiency Achievement

Elimination of air mixing and waste reduces carbon footprint by 50% while improving overall system sustainability performance.

how-product-1

Cage System

A modular suite for optimized data hall management which offers security, scalability, and modularity.

Our modular panel system allows the design and construction of cages in any footprint and data hall heights.

product-system-cage
product-system-cage-1
product-system-cage-2
product-system-cage-3

Join the Our Data Center
Revolution

Transform your facility into an eco-friendly, cost-efficient operation while meeting sustainability goals and regulatory requirements

Find Us:

Contact Us: